FAQ #387
Insulation Monitoring Device Startup
Last Updated On
1/9/2025 06:36:29 PM
by
sayovitz
Question
When the Insulation Monitoring Device is first started, it shows a fault for several seconds.
How does this affect the IMD Indicator Light and the Tractive System Status Indicator?
Answer
Formula SAE Rules 2025 section EV.7.6 does not include the Insulation Monitoring Device startup process.
The IMDs usually used for Formula SAE Electric may give a fault during the startup process. This is the design of the IMD and cannot be changed.
For teams to design their monitoring circuit, more guidance is provided below. Per Formula SAE Rules GR.4.3.2, this guidance supplements the Formula SAE Rules
During the IMD startup period:
1. EV.7.6.4 and EV.7.6.5 do not apply since the IMD is not able to monitor the Tractive System until the startup is complete
2. The IMD Indicator Light EV.7.6.6 may be ON
3. The Tractive System Status Indicator must meet EV.5.11.5 at all times. Indication of a fault (EV.5.11.5.b) will be a Red Car Condition EV.12
4. A hardware or software method may be included to prevent the false positive Tractive System Status Indicator indication
When the IMD startup is completed:
EV.7.6.4 and EV.7.6.5 must be met when the Low Voltage (GLV) system is ON
No Attachments
Rule Numbers
2025:EV.7.6.4
2025:EV.7.6.5